Wear compliance and activity in children wearing wrist and hip mounted accelerometers

Fairclough, Stuart, Noonan, Robert, Rowlands, Alex, van Hees, Vincent, Knowles, Zoe and Boddy, Lynne (2016) Wear compliance and activity in children wearing wrist and hip mounted accelerometers. Medicine & Science in Sports & Exercise, 48 (2). pp. 245-253. ISSN 0195-9131 DOI https://doi.org/10.1249/MSS.0000000000000771

This is the latest version of this item.

[img]
Preview
PDF
GA_vs_AG_raw_compliance__PA_paper_MSSE_REVISION_CLEAN3.pdf - Accepted Version

Download (362kB)

Abstract

Purpose. This study aimed to (i) explore children’s compliance to wearing wrist and hip-28 mounted accelerometers, (ii) compare children’s physical activity (PA) derived from wrist 29 and hip raw accelerations, and (iii) examine differences in raw and counts PA measured by 30 hip-worn accelerometry. 31 Methods. One hundred and twenty nine 9-10 y old children wore a wrist-mounted 32 GENEActiv accelerometer (GAwrist) and a hip-mounted ActiGraph GT3X+ accelerometer 33 (AGhip) for 7 d. Both devices measured raw accelerations and the AGhip also provided 34 counts-based data. 35 Results. More children wore the GAwrist than the AGhip regardless of wear time criteria 36 applied (p<.001 - .035). Raw data signal vector magnitude (SVM; r = .68), moderate PA 37 (MPA; r = .81), vigorous PA (VPA; r = .85), and moderate-to-vigorous PA (MVPA; r = .83) 38 were strongly associated between devices (p<.001). GAwrist SVM (p = .001), MPA (p = 39 .037), VPA (p = .002), and MVPA (p = .016) were significantly greater than AGhip. 40 According to GAwrist raw data, 86.9% of children engaged in at least 60 min MVPA∙d-1, 41 compared to 19% for AGhip. ActiGraph MPA (raw) was 42.00 ± 1.61 min∙d-1 compared to 42 35.05 ± 0.99 min∙d-1 (counts) (p=.02). Actigraph VPA was 7.59 ± 0.46 min∙d-1 (raw) and 43 37.06 ± 1.85 min∙d-1 (counts; p=.19). 44 Conclusion. In children accelerometer wrist placement promotes superior compliance than 45 the hip. Raw accelerations were significantly higher for GAwrist compared to AGhip, 46 possibly due to placement location and technical differences between devices. AGhip PA 47 calculated from raw accelerations and counts differed substantially, demonstrating that PA 48 outcomes derived from cutpoints for raw output and counts cannot be directly compared.

Item Type: Article
Subjects: Q Science > Q Science (General)
Divisions: Sports Science
Related URLs:
Date Deposited: 18 Feb 2016 10:55
URI: http://repository.edgehill.ac.uk/id/eprint/7089

Available Versions of this Item

Archive staff only

Item control page Item control page